Connect Modbus TCP Devices to BACnet/IP

Connect Modbus TCP devices into your BACnet/IP enabled building automation systems

460MCBS

$896.72$1,251.75

SKU: 460MCBS

INCLUDES
PRODUCT FEATURES
DATASHEETS & USERGUIDES

Integrate Your Modbus TCP Servers Into Your BACnet/IP Building Management System
The 460MCBS moves data between up to 32 Modbus TCP Servers and a BACnet/IP Building Automation System (BAS). It’s a perfect tool to tie Modbus TCP power meters, boilers, chillers and other devices into your BACnet/IP Building Automation System.

Best of all the product is Made in the USA, is always in stock and comes with 5 year warranty.

How Do I Use the 460MCBS in My Application?
For Most applications the mapping is very straight forward. Modbus TCP register data is mapped to BACnet/IP analog objects and Modbus TCP coil data is mapped to binary objects on BACnet/IP. The only additional piece required for BACnet/IP is adding meta data which is nothing more than an ASCII description of each object. No other deep understanding of either protocol is required to configure the gateway.

It really is that simple. Need to modify your data as it passes from one protocol to the other? No problem. Each data mapping you apply can be modified with up to 3 mathematic functions. Add 4 to a value, multiply by 4 and divide by 10 with ease.

Why Use Real Time Automation as a Gateway Supplier?
The 460MCBS provides an option to access Modbus TCP server devices on your BACnet/IP client. While there are certainly a number of other companies offering stand alone gateways, there is no one who provides the level of support and service that you receive from RTA.

When you call, a live person answers the phone. When you talk with sales, you will get honest answers and recommendations even if that means recommending someone else’s solution. When you get support, it is from an engineer who had a hand in the product’s development, and support doesn’t require a ticket or 24 hour wait.We are unashamed of the fact that we are a smaller company because that means you mean a lot more to us. Try the RTA difference today.

Modbus TCP/IP Client Features

Modbus Operation Modes: Modbus TCP/IP Client
Function Codes Supported: 1, 2, 3, 4, 5, 6, 15 and 16
Swapping: Byte and Word Swapping
Maximum Modbus TCP/IP Server Devices: 32
Number Read/Write Scan Lines per Server Device: 200 Total - 100 reads & 100 writes
Scan Line Support: Up to 125 Registers or 512 Coils

BACnet/IP Server Features

BACnet/IP Operation Modes: BACnet/IP Server
Supported Object Types: Device, Binary I/O, Analog I/O, Character String Value
Supported Service Codes: Read & Read Multiple-B, Write & Write Multiple-B, COV & COV unsolicited-B, Device Dynamic Binding, Dynamic Object Binding-B, Device Communication Control-B
Maximum Connections: 1
Analog Objects Supported: 1200 Input and 1200 Output
Binary Objects Supported: 1600 Input and 1600 Output