Connect Allen-Bradley PLCs to BACnet/IP

A simple way to integrate Allen-Bradley PLCs into your BACnet/IP building automation systems

460ETCBS

$896.72$1,251.75

SKU: 460ETCBS

INCLUDES
PRODUCT FEATURES
DATASHEETS & USERGUIDES

Connect Your Allen-Bradley PLCs To Your Building Automation System

Many building systems use Programmable Controllers to implement building control logic. Until now, it has been difficult and expensive to exchange data between Allen-Bradley PLCs and BACnet/IP enabled Building Automation Systems (BAS). For some Allen-Bradley PLCs there were no devices that would connect it to a BAS.

That’s Where the 460ETCBS Comes in

The 460ETCBS changes all that and gives you an amazing tool to quickly and easily integrate your BACnet/IP enabled BAS with any Allen-Bradley PLC. Even the legacy PLC5Es and SLC 5/05s. With this small, din rail module you can now use BACnet/IP Analog and Binary Properties to access the registers or tags in your Allen-Bradley PLC.

How Does the Data Move In and Out of the PLC?

To transfer data between a BACnet/IP Controller and up to five Allen-Bradley PLCs, the PLCs must allocate memory space to receive data and memory space to transmit data. In new PLCs, the memory space can consist of an individual tag, a tag array or a User Defined Tag (UDT) structure. In legacy PLCs, the memory space consists of two sets of register blocks.

The 460ETCBS store data received from a BACnet/IP controller in the area designated to receive data. It gets data to transmit to a BACnet/IP controller from the area designated to transmit data. BACnet/IP controllers exchange objects with end devices like the 460ETCBS. The 460ETSBS supports the Analog Input, Analog Output and Binary Input and Binary Output objects. It maps these objects into the PLC memory areas designated to send and receive BACnet/IP data.

It’s really that simple. Need to modify your data as it passes from one protocol to the other? No problem. Each data mapping you apply can be modified with up to 3 mathematic functions. Add 4 to a value, multiply by 4 and divide by 10 with ease.

Why Use Real Time Automation as a Gateway Supplier?

The 460ETCBS provides an option to access a BACnet/IP system with an Allen-Bradley PLC without an expensive in-rack solution. While there are certainly a number of other companies offering stand alone gateways, there is no one who provides the level of support and service that you receive from RTA.

When you call, a live person answers the phone. When you talk with sales, you will get honest answers and recommendations even if that means recommending someone else’s solution. When you get support, it is from an engineer who had a hand in the product’s development, and support doesn’t require a ticket or 24 hour wait. We are unashamed of the fact that we are a smaller company because that means you mean a lot more to us.

Try the RTA difference today and give us a call at 1-800-249-1612

BACnet/IP Server Features

BACnet/IP Operation Modes: BACnet/IP Server
Supported Object Types: Device, Binary I/O, Analog I/O, Character String Value
Supported Service Codes: Read & Read Multiple-B, Write & Write Multiple-B, COV & COV unsolicited-B, Device Dynamic Binding, Dynamic Object Binding-B, Device Communication Control-B
Maximum Connections: 1
Analog Objects Supported: 1200 Input and 1200 Output
Binary Objects Supported: 1600 Input and 1600 Output

EtherNet/IP Tag Client Features

PLC Support: ControlLogix, CompactLogix, FlexLogix, MicroLogix, SLC’s and PLC5E’s
Maximum Number of PLCs Supported: 5
Maximum Number Read Tags or Registers Supported: 150 per PLC
Maximum Number Write Tags or Registers Supported: 150 per PLC
Array Support: Yes, for all data types except strings
Supported Data Types: ControlLogix / CompactLogix / FlexLogix: Bit, 32 Bit Array, SINT, INT, REAL, STRING, DINT, MicroLogix / SLC / PLC5E: 16 Bit Array, INT, REAL, STRING

What our Customers are Saying

“I challenged a customer to get it working by the time I got back from his break room with a Coke and he indeed had it working when I got back. He then said, "It’s worth twice the price!"”

Eric P. / Kendall Electric

“Everything seems to be working as we imagined. Thanks for the great response time. I did not see any way to save the configuration other than screen shots, but the configuration did not get lost in the update. Thanks again, and you were a pleasure to work with.”

Kevin L. / Extol, Inc.