Connect Profibus to BACnet/IP Gateway

Connects a BACnet/IP Client with a PROFIBUS Controller

460BSPBS

$941.28$957.03

SKU: 460BSPBS

INCLUDES
PRODUCT FEATURES
DATASHEETS & USERGUIDES

Connect a BACnet/IP Client Device to a Profibus Controller
The 460BSPBS moves data between a BACnet/IP Client and a Profibus DP Controller. It’s the perfect tool to tie all the BACnet/IP devices in your automation system to Profibus. Bridge your factory automation systems with your building automation systems.

How Do I Use 460BSPBS-NNPB in My Application?
BACnet/IP data will be mapped into 10 Profibus DP slots. Each slot will be assigned a type of Int8, int16, int32, int64, Uint8, Uint16, Uint32, Uint64, float, double, binary8, binary16, or binary32. The slot can consist of up to 244 bytes of data from your BACnet/IP Client device.

Why use Real Time Automation as a Gateway Supplier?
While there are certainly other companies offering protocol gateways, there is no one who provides the level of support and service that you receive from RTA.

When you call, a live person answers the phone. When you talk with sales, you will get honest answers and recommendations. When you get support, it is from an engineer who had a hand in the product’s development, and support doesn’t require a ticket or 24-hour wait.

Try the RTA difference today.

BACnet/IP Server Features

BACnet/IP Operation Modes: BACnet/IP Server
Supported Object Types: Device, Binary I/O, Analog I/O, Character String Value
Supported Service Codes: Read & Read Multiple-B, Write & Write Multiple-B, COV & COV unsolicited-B, Device Dynamic Binding, Dynamic Object Binding-B, Device Communication Control-B
Maximum Connections: 1
Analog Objects Supported: 1200 Input and 1200 Output
Binary Objects Supported: 1600 Input and 1600 Output

Profibus Slave Features

Object Model: 10 Slots in each direction
Slot Size: 2, 4, 8, 16, 24, 32 Bytes
Data Representation: int8, int16, int32, int64, uint8, uint16, uint32, uint64, Float, Double, binary8, binary 16, binary 32, Short String
Total Data Supported: 244 Bytes in each direction
Maximum Profibus DP Connections: 1

What our Customers are Saying

“I challenged a customer to get it working by the time I got back from his break room with a Coke and he indeed had it working when I got back. He then said, "It’s worth twice the price!"”

Eric P. / Kendall Electric

“Everything seems to be working as we imagined. Thanks for the great response time. I did not see any way to save the configuration other than screen shots, but the configuration did not get lost in the update. Thanks again, and you were a pleasure to work with.”

Kevin L. / Extol, Inc.