TCP to ControlLogix EtherNet/IP™ Gateway

The Fastest Way to Move Barcode, Scale and Other TCP Data to a ControlLogix PLC
 
490nba Ethernet/IP image
  Get More Info  
  Get Price List  
  White Paper  
  View Datasheet  
     
Chat with us
CLICK HERE TO CHAT WITH US
 
   
For Immediate Information Call:  
Sales  
1-800-249-16121-414-453-5100  
   
     

Ethernet is no longer an option for Industrial Devices – ETHERNET IS A REQUIREMENT. Ethernet is the fastest growing segment of Industrial Networking for one reason – The Market (Your Customers) Loves Ethernet. And the most important Industrial Ethernet protocol is EtherNet/IP™. EtherNet/IP is the Ethernet solution used in the Rockwell Automation architecture and the one GM is requiring for Robots, Welders and other automation devices.

Even though Ethernet is the standard there is still an awful lot of raw TCP data out there. There is a ton of perfectly good scales, barcode readers, RF ID stuff and lots of other things that generate a TCP string. This is equipment that you've used for a long time. You know how to set it up, how to make it work and that it's reliable for you. Plus, you can probably get it a really good price since it doesn't have all the fancy features of the new models.

The problem is that you still have to get this stuff into your PLC. And front panel serial ports are going the same way as PC serial ports. So, you've probably used these serial tunneling devices. They work fine to a point. You still have to receive the serial data and move it into PLC registers. That means writing and testing plc logic. Not hard – just another task to do and more code to support. But there is a better way, a much better way. If you could move the data right into the PLCs registers it would not only save you commissioning time, it get your barcode or scale data into those registers faster without any overhead.

Well, that's the device that we have. It quickly and easily moves Barcode data, Weigh Scale data and other TCP devices to ControlLogix PLCs using EtherNet/IP. Using EtherNet/IP Client technology the 490NBA EtherNet/IP gateway moves your raw TCP data to a ControlLogix PLC with little or no delay. Milliseconds after receiving your raw TCP data on either of the two serial ports your data is transferred to your user-specified tag in the PLC. Simply configure the input data format, the IP Address of the ControlLogix PLC and a PLC tag for each serial port using a very simply browser interface and you are ready to run. No standalone or custom software is required. It's that simple!

 
Application Diagram
 
EtherNet/IP™ 490 NBA Application Diagram image
top of page
 
Virtual Data Paths
Ethernet/Ip Virtual Data Paths image
top of page
 
Features
  • Specifically designed for Barcode Readers, Weigh scales and other TCP devices
  • Dual TCP Port Data Transfer - Supports maximum six devices on two TCP channels
  • Independent ControlLogix Tags for each TCP Channel
  • Simple, easy-to-use Configuration Using Any Browser
  • Fully Compatible with Rockwell ControlLogix EtherNet/IP Communications Module
  • Simple Handshaking Protocol ensures no Lost Messages
  • EtherNet/IP Client Technology
  • ODVA Conformance Testing Pending
top of page
 
Benefits
  • An Optimized Solution for Transferring your Barcode and Scale data to a ControlLogix PLC
  • Reduce Your Investment by Networking multiple TCP devices with a single module
  • Transfer data from multiple TCP devices independently and simultaneously
  • Transfer data to multiple TCP devices independently and simultaneously
  • Support lots of devices with vastly different TCP data formats
  • Seamlessly Integrate your TCP devices with Rockwell Automation ControlLogix
  • No Lost Messages
  • Proven and reliable hardware platform
  • Transfer data with Little or No Latency
top of page
 
Sample Configuration Screen
 
Real Time Automation, Inc. PLC5E Raw TCP Messenger
Description
RTA, Inc. PLC5E Msngr: Enter descr.
PLC5E communication is enabled
PLC5E IP address = 192.100.100.80

Raw TCP Gateway 0 is enabled
IP Address = 0.0.0.0
Port = 50200

Raw TCP to PLC5E
Buffer transmit length = 200
PLC5E FileAddress = N7:0

PLC5E to Raw TCP
Buffer transmit length = 40
Poll Time = 10000
PLC5E FileAddress = N7:0
End delimiter byte1 = [CR] 13 0x0D
End delimiter byte2 = [LF] 10 0x0A

Raw TCP Gateway 1 is disabled
Edit
Network Settings
IP address: 192.100.100.165
Subnet mask: 255.255.255.0
Default gateway: 192.168.0.1

Edit
MAC address: 00-03-F4-01-5E-6A
Revision: 1.0
 

ORDERING INFORMATION

490NBA

Logix1 Raw TCP Dual Port EtherNet/IP Gateway

Desk Mounted Gateway

490NBA-P

Logix Raw TCP Dual Port EtherNet/IP Gateway

Panel Mounted Gateway

490NBA-D

Logix Raw TCP Dual Port EtherNet/IP Gateway

Din Rail Mounted Gateway

490NBP

PLC5 Raw TCP Dual Port EtherNet/IP Gateway

Desk Mounted Gateway

490NBP-P

PLC5 Raw TCP Dual Port EtherNet/IP Gateway

Panel Mounted Gateway

490NBP-D

PLC5 Raw TCP Dual Port EtherNet/IP Gateway

Din Rail Mounted Gateway

490NBS

SLC5/05, MicroLogix Raw TCP Dual Port EtherNet/IP Gateway

Desk Mounted Gateway

490NBS-P

SLC5/05, MicroLogix Raw TCP Dual Port EtherNet/IP Gateway

Panel Mounted Gateway

490NBS-D

SLC5/05, MicroLogix Raw TCP Dual Port EtherNet/IP Gateway

Din Rail Mounted Gateway

1 Logix refers to both ControlLogix and CompactLogix

 
Find out more about the Get it Done For You! Program
top of page